Cable Height Sensor 1m
Application = TEBS E (GIO) Cable end (left side of diagram) = Bayonet socket ISO 15170-B1-2.1-Sn/K1 4-pin Cable end (right side of diagram) = Code B 4-pin Calculated Volume (dm³) = 4.142 Length =...
Application = TEBS E (GIO) Cable end (left side of diagram) = Bayonet socket ISO 15170-B1-2.1-Sn/K1 4-pin Cable end (right side of diagram) = Code B 4-pin Calculated Volume (dm³) = 4.142 Length =...
Application = TEBS E (GIO) Cable end (left side of diagram) = Bayonet socket ISO 15170-B1-2.1-Sn/K1 4-pin Cable end (right side of diagram) = Code B 4-pin Calculated Volume (dm³) = 4.6626 Length =...
Application = ECAS solenoid valve: Trailer EBS E Cable end (left side of diagram) = Bayonet socket ISO 15170-B1-3.1-Sn/K1 4-pin Cable end (right side of diagram) = Code B 4-pin Calculated Volume...
Application = TEBS E (GIO) Cable end (left side of diagram) = Bayonet socket ISO 15170-B1-2.1-Sn/K1 4-pin Cable end (right side of diagram) = Code B 4-pin Calculated Volume (dm³) = 5.044 Length =...
Application = ECAS Cable end (left side of diagram) = Bayonet socket ISO 72585-B1-4.1-Sn/K1 4-pin Cable end (right side of diagram) = Open 4-Strand with push-on contacts and PG screw connection 4 x...
Application = Pressure sensor: Trailer EBS E Cable end (left side of diagram) = Bayonet socket ISO 15170-B1-3.1-Sn/K1 4-pin Cable end (right side of diagram) = Code B 4-pin Calculated Volume (dm³) =...
Application = Diagnosis Cable end (left side of diagram) = Diagnosis socket with blue cap 7-pin Cable end (right side of diagram) = X6 auxiliary plug 8-pin Calculated Volume (dm³) = 5.8 Length =...
Application = Diagnosis: Trailer EBS E Cable end (left side of diagram) = Diagnosis socket with yellow cap 7-pin Cable end (right side of diagram) = Code B 4-pin Calculated Volume (dm³) = 5...
Application = VCS Cable end (left side of diagram) = Diagnosis 5-pin Cable end (right side of diagram) = Diagnosis socket with blue cap 7-pin Calculated Volume (dm³) = 6.4705 Length = 3m Size (mm x...
Application = Diagnosis: Trailer EBS E Cable end (left side of diagram) = Diagnosis socket with yellow cap 7-pin Cable end (right side of diagram) = Code B 4-pin Calculated Volume (dm³) = 5...
Cable end (left side of diagram) = Diagnosis socket with blue cap 7-pin + bayonet socket ISO 15170-B1-3.1-Sn/K1 4-pin Cable end (right side of diagram) = X6 auxiliary plug 8-pin Calculated Volume...
Cable end (left side of diagram) = Diagnosis socket with blue cap 7-pin + bayonet socket ISO 15170-B1-3.1-Sn/K1 4-pin Cable end (right side of diagram) = X6 auxiliary plug 8-pin Calculated Volume...